4.2.1 Due to their inherent strength and robustness, the lifespan of tall buildings can often extend over numerous decades. Allowing these structures to be reimagined to meet the needs of future generations is the key to unlocking their survival. The adaptive reuse and reinventing of our tall building stock is therefore one of the most sustainable forms of development that can help extend the lives of these buildings while regenerating brownfield sites. Repurposing tall buildings that may have outlived their intended use can breathe life into these structures and provide new floorspace opportunities often within busy, inner city locations. While each case would need to be assessed on its own merits, in principle the Council supports the adaptive and sustainable reuse of tall buildings across the city.

4.2.2 Balancing the retention of the tall building’s architectural and historic integrity against its repurposed use is vital. This is particularly so where the tall building in question is within the setting of a heritage asset or is considered to contain locally distinctive features. Where this is the case, every opportunity should be taken to retain as much of the character of the building as possible, be these external and/or internal, to avoid costly reconstruction work and get the building back into use over a short space of time.

4.2.3 Conversely where a tall building is not considered to contribute to the character of an area, the opportunity may exist to reimagine the building on a large scale so that it responds more positively to its surrounding context and setting of built heritage assets. In these cases, a more flexible approach may be taken in relation to a comprehensive reimagining scheme, however justification for doing so will need to be provided as part of a Tall Buildings Design Statement (TBDS) - see Section 6.

Images 9 and 10:  Grand Central Hotel, Bedford Street

Reimagining and refurbishment of the landmark 1970s Windsor House into a 4-star 300 bed signature hotel that sits more comfortably within the context of the historic Linen Quarter.

Picture9tb_1

Picture10tb_1

4.2.4 Across Ireland and the UK there are many examples of buildings constructed in the 1960s, 1970s and even the 1980s, where often due to their architectural language and style being out of vogue, consideration is given in the first instance to their demolition. While this may be the only viable option for those that are structurally unsound and cannot be viably retained, efforts in these instances should at least be made to salvage as much of the existing material from the building as possible. Where the building structure is sound and the layout of floorplates are flexible, a reuse and renew approach is encouraged. Any proposed net gains in the form of extensions and/or additional storeys will need to be justified as part of the TBDS.

4.2.5 How much new floorspace that can be added to an existing building will often be predicated by the floor loadings imposed on its original design, which if constructed during the 1960s to 1980s tended to be over specified. Adding one or two additional storeys to an existing structure, as enabling works to maximise its capacity and bring the building back into use, is generally widely accepted so long as there is no discernible adverse impact arising from the new build. These can include any impacts on the setting of listed buildings, conservation areas, ATC’s, amenity, overshadowing and poor design quality. To ensure that the original integrity of the building is not compromised and that the final reimagined building is contextually appropriate, careful consideration will need to be given to those schemes which claim to require a number of additional storeys to warrant the reuse of the building viable.

4.2.6 Our urban environments include high-rise commercial buildings constructed over the last fifty years where façades are either failing, deteriorating or due to the time period in which they were built, look dated and no longer relevant to their changing context. These buildings, often located at prominent sites, can present reimagining opportunities that sees the bulk of the building being retained with its existing skin shed for a new one. Advances in building construction technology have seen a rise in these failing and dated façades being replaced by new façades which can include curtain walling systems. The use of curtain walling systems as a façade replacement not only enables the external appearance of the building to be transformed but also offers better weatherproofing, improved energy efficiencies, operational cost savings and increased marketability. Additional benefits also include increased light penetration to the building, improved comfort for users and enhanced views out to the surrounding urban landscape. 

4.2.7 Consideration should be given to the use of openable windows in conjunction with energy efficiency and comfort levels to enable the circulation of fresh rather than conditioned air, which is especially appropriate in the current climate.